| http://www.w3.org/ns/prov#value | - The problem with ASTM A500 is that according to the Note 1 of the Scope products manufactured to that specification may not be suitable for those applications such as dynamically loaded elements in welded structures, etc., where low-temperature notch-toughness properties may be important.To make the long story short: they are not certified for low temperature service.
|